Document Type
Journal Article
Publication Title
Journal of Renal Care
Publisher
Wiley
School
School of Nursing and Midwifery / Centre for Research in Aged Care / Centre for Nursing, Midwifery and Health Services Research
RAS ID
36258
Funders
Edith Cowan University Early Career Research grant. Grant Number: G1004430
Abstract
Background The Western Australian Haemodialysis Vascular Access Classification instrument was developed to classify the cannulation complexity of the arteriovenous fistula or arteriovenous graft as simple, challenging, or complex. Although the instrument was developed by experts in haemodialysis nursing, the instrument had not undergone formal validity or reliability testing. Objectives Evaluate the Western Australian Haemodialysis Vascular Access Classification instrument for content validity, interrater and test–retest reliability. Design Prospective cohort study. Participants Content validity was assessed by haemodialysis nursing experts (n = 8). The reliability testing occurred in one in-centre and one satellite haemodialysis unit in Western Australia from September to November 2019. Reliability testing was performed by 38 haemodialysis nurses in 67 patients receiving haemodialysis and 247 episodes of cannulation. Measurements Interrater and test–retest reliability assessment was conducted using κ, adjusted κ, Bland–Altman plots, intraclass correlation coefficient and Pearson's correlation coefficient. Results The final version of the instrument (n = 20 items) had individual item-level content validity indices ranging from 0.625 to 1.00 with a scale-level content validity index of 0.89. For both interrater (n = 172 pairs) and test–retest (n = 101 pairs), most individual variables had excellent adjusted κ (n = 33 variables), some fair to good agreement (n = 6 variables) and one variable with poor agreement. The classification of simple, challenging and complex demonstrated adjusted κ of fair to good, to excellent agreement for interrater reliability with lower levels of agreement for test–retest reliability. Conclusions This instrument may be used to match a competency-assessed nurse to perform the cannulation thereby minimising the risk of missed cannulation and trauma.
DOI
10.1111/jorc.12390
Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.
Comments
Coventry, L. L., Hosking, J., Coral, E., Jenkins, M., Salgado Kent, C. P., Chan, D., ... & Rickard, C. M. (2022). The development of the Western Australian Haemodialysis Vascular Access Complexity instrument. Journal of Renal Care, 48(3), 185-196. https://doi.org/10.1111/jorc.12390