Evaluating environmental ward performance: Insights from acoustic, lighting, and temperature monitoring in a palliative care unit

Author Identifier (ORCID)

Emil E. Jonescu’s ORCID record ORCID Logo

Abstract

The physical environment of inpatient wards plays a critical role in supporting rest and care delivery. In palliative care, environmental conditions such as sound, lighting, and temperature directly influence patient comfort, circadian rhythms, and staff performance. However, few studies have quantitatively assessed these factors in functioning palliative care units (PCUs). Objectives: To evaluate the spatial and environmental performance of an acute PCU through sensor-based monitoring of acoustic exposure, light levels, and temperature. Method: A postoccupancy evaluation approach was employed to assess conditions within inpatient rooms. Environmental loggers recorded data continuously at 1-min intervals across two 1-month periods. Parameters included sound levels (Lmax, Leq, Lmin in A-weighted decibels) to reflect perceived loudness, lighting (lux), and temperature (°C). Measurements were benchmarked against World Health Organization and Australian guidelines for sleep-supportive healthcare environments. Data were collected from both single- and multibed rooms in a metropolitan tertiary hospital PCU. Results: Sound levels frequently exceeded recommended thresholds. Nighttime averages reached 54 dB(A), while daytime LAeq exceeded 60 dB(A), with minimal day–night variation (<6 dB), indicating sustained exposure. Lighting data showed repeated nighttime spikes above 20 lux and insufficient daytime illumination for circadian regulation. Temperature exhibited minimal diurnal variation (<2°C), falling short of conditions known to support sleep. Conclusion: Environmental monitoring revealed persistent deviations from sleep-supportive conditions. These stressors likely impact both patient well-being and staff performance. Findings underscore the need for evidence-based design strategies and translational research that position the built environment as an active contributor to holistic care. In palliative contexts, architectural design should enable rather than simply contain clinical practice.

Keywords

environmental monitoring, healthcare spatial performance, light, noise, palliative care, PCU, postoccupancy evaluation, sound, temperature

Document Type

Journal Article

Date of Publication

1-1-2026

ISSN

19375867

Publication Title

HERD: Health Environments Research & Design Journal

Publisher

Sage

School

School of Arts and Humanities

Copyright

subscription content

Content Type

Metadata only

Recommended Citation

Jonescu, E. E., Farrell, B., Ramanayaka, C. E., Delaney, L., Litton, E., Uylaki, T. J., Watts, G., Asad, S., Brigham, B., Bellemore, F., & Seah, D. (2026). Evaluating environmental ward performance: Insights from acoustic, lighting, and temperature monitoring in a palliative care unit. HERD: Health Environments Research & Design Journal. Advance online publication. https://doi.org/10.1177/19375867261455034

Share

 
COinS
 

Link to publisher version (DOI)

10.1177/19375867261455034